  • Voltage drop workbenchCheck a twin and earth run against the 3% or 5% allowance
  • CalculatorsVoltage drop, cable sizing, Max Zs and more in the workspace
  • Pricing and plansCompare Free and Pro
  • QuestionsSchemes, phones, cancellation and regulations
  • Help CentreStep-by-step guidance for VoltMate
  • Blog and communityElectrical knowledge, updates and discussions
  • Contact supportGet help with your account or workflow
↑ ↓ to move · Enter to openEsc to close
Help Centre

AI & technical tools

Calculators

Run preliminary electrical calculations and review checklists for voltage drop, cable sizing, maximum demand, protective devices, earth fault loop, RCDs, EV, solar and battery work.

calculatorcalculatorsvoltage dropcable sizecable sizingmaximum demand

Before you begin

  • A VoltMate account.

What the calculators cover

  • Three-Phase Load & Balance, Circuit Load, Ohm's Law and a General Calculator for everyday electrical arithmetic.
  • Voltage Drop and Cable Size Assistant for preliminary cable checks from length, load and cable data.
  • Maximum Demand for connected load and preliminary maximum demand.
  • Protective Device Helper, Earth Fault Loop and RCD Selection to compare device and protection considerations.
  • EV Charger Assistant, Solar PV Assistant and Battery Storage to review supply, load, earthing and connection inputs for that work.

Formula tools

Formula tools, at the end of the Calculators page, are quick checks from standard formulas, grouped by subject. Each shows the formula it uses, the assumptions and any warnings with the result. Values that come from reference tables or data sheets, such as a k factor, a maximum Zs, a touch voltage limit or a cable's resistance, are entered by you; VoltMate does not fill them in.

Formula tools for testing and protection

  • Ring Final Circuit Continuity: the R1 + R2 and L–N values to expect at each socket from end-to-end r1, rn and r2 readings, and whether r1 and rn agree within your tolerance.
  • Conductor Resistance at Temperature: converts a resistance measured at one conductor temperature to another, for example a cold reading to operating temperature.
  • Prospective Fault Current: U₀ ÷ Z, compared with a breaking capacity if you enter one.
  • Protective Conductor Size (Adiabatic): the smallest protective conductor for a fault current, a disconnection time of up to 5 s and your k factor.
  • Maximum Cable Length (Earth Fault Loop): the longest run that keeps Zs within the maximum you enter, from Ze and the cable's R1 + R2 per metre.
  • TT Earth Electrode and RCD: RA × IΔn against the touch voltage limit you enter, and the highest RA for that RCD.
  • Earth Rod Resistance: an estimate for a single vertical rod from the soil resistivity, rod length and diameter. Always measure the installed electrode.

Formula tools for design, supply and three-phase

  • Maximum Cable Length (Voltage Drop): the longest run that keeps voltage drop within your limit, using the same three-phase method as Voltage Drop.
  • Power Factor Correction: the capacitor kVAr to raise a load's power factor, with the apparent power and current before and after.
  • Power Triangle: apparent and reactive power and the phase angle from real power and power factor.
  • Transformer Current: full-load current from the rating and voltage, and the fault current at the terminals from the percentage impedance.
  • Star and Delta Values: phase voltage and current of a balanced star or delta load from its line values.
  • Three-Phase Neutral Current: the neutral current from the three phase currents. Harmonics from electronic loads can make it higher.
  • Resistances in Series and Parallel: totals for up to four resistances.

Formula tools for renewables, EV, lighting and customer advice

  • DC Voltage Drop: the drop on a two-wire DC circuit, such as a PV string or battery cable, from the conductor resistance in the cable data.
  • Battery Runtime: how long a battery runs a steady load through an inverter, from its capacity and the usable depth of discharge.
  • EV Charging Time: time and energy for a charge from the battery size, the charge levels and the charger power.
  • Lighting Level (Lumen Method): average illuminance from the luminaires, and how many are needed for a target level.
  • Energy Use and Running Cost: kWh and cost for a load's hours of use at your unit price.
  • Water Heating Time: time and energy to heat a volume of water with a given heater power.

Formula tools for AC circuits and fundamentals

  • Capacitive Reactance: XC = 1 ÷ (2π f C) for a capacitance in µF, with the current and the reactive power the capacitor supplies (leading) at a voltage you enter.
  • Inductive Reactance: XL = 2π f L for an inductance in mH, with the current and the reactive power the inductor absorbs (lagging) at a voltage you enter.
  • Series RLC Impedance: the impedance, phase angle, power factor and current of a resistance, an inductance and an optional capacitance in series, with the voltage across L and C, which can be well above the supply near resonance.
  • Resonant Frequency: the frequency at which an inductance and a capacitance resonate, and the reactance of each at that frequency.
  • Capacitors in Series and Parallel: series and parallel totals for up to four capacitances of 1 pF or more, entered in µF and shown in nF below 0.1 µF or in pF below 0.1 nF.
  • Inductors in Series and Parallel: series and parallel totals for up to four inductances of 1 nH or more, entered in mH and shown in µH or nH when small, assuming the coils are not magnetically coupled.
  • Voltage Divider: the output of two resistors in series, with and without a load across the lower one, and the currents drawn, in µA when below 0.1 mA.
  • Sine Wave Values: the RMS, peak, peak-to-peak and half-cycle average values from any one of them, in V, A or mA, for a pure sine wave only.
  • Frequency and Period: the period, half-cycle time and angular frequency from the frequency.
  • Resistive Load at Another Voltage: the power and current of a heater element or other purely resistive load at a voltage other than its rating, with a warning when the voltage is above the rating.
  • Decibel Ratio: the ratio of two powers, voltages or currents in decibels, where the voltage or current form matches the power ratio only across equal impedances.

Formula tools for motors and drives

  • Motor Full-Load Current: an estimate from the rated output, efficiency and power factor on a single-phase or three-phase supply, for when the nameplate current is not available.
  • Motor Starting Current: direct-on-line, star-delta and soft-starter starting currents from the full-load current and the starting multiple you take from the motor data.
  • Motor Synchronous Speed and Slip: the synchronous speed from the frequency and number of poles, and the slip at the rated speed you enter.
  • Motor Torque: shaft torque from power and speed, or the power a torque needs at that speed.
  • Drive Output Frequency and Speed: the approximate speed of an induction motor at a drive's output frequency, and the frequency for a target speed, with a warning when the rated speed does not suit the rated frequency, such as a 60 Hz nameplate speed.
  • Fan and Pump Affinity Laws: how flow, pressure and power fall when a centrifugal fan or pump is slowed, with the yearly shaft energy and cost saved at your hours and unit price.
  • Motor Efficiency and Losses: efficiency and losses from the electrical input and mechanical output, and the yearly cost of the losses.
  • Motor Power from Measured Current: input and apparent power from a measured current, voltage and power factor, and the output if you enter an efficiency.
  • Generator Size: the kW and kVA ratings a set needs for a running load plus the margin you choose, worked from the lower of the load and set power factors, with the full-load current, to be confirmed with the generator maker's sizing.
  • Belt and Pulley Speed: the driven speed, speed ratio and belt speed from the driver speed and the two pulley diameters.

Formula tools for supply, transformers and power quality

  • Transformer Turns Ratio: the turns ratio Np ÷ Ns of an ideal transformer from its turns, or the voltage ratio Vp ÷ Vs from its voltages, with the current on the other side if you enter one, keeping to winding values or line values throughout for three-phase.
  • Transformer Efficiency: the efficiency at a load and power factor from the no-load and full-load losses in the maker's data, and the load at which efficiency is highest.
  • Transformer Size for a Load: the kVA needed for a load's kW and power factor plus the margin you choose, with the full-load current of a single-phase or three-phase transformer at that size, for you to match to a rating in the manufacturer's range.
  • Supply Voltage Tolerance: how far a measured voltage is from 230 V or 400 V against the statutory range of +10 % −6 %, with a reading outside it to be reported to the distribution network operator.
  • Voltage Unbalance: the negative-sequence unbalance used by IEC standards and EN 50160, and the NEMA MG 1 line-voltage figure, from three line-to-line voltages, compared with a limit if you enter one under the definition it is written for.
  • Total Harmonic Distortion: THD and total RMS from the fundamental and up to five harmonic magnitudes, compared with a limit if you enter one.
  • Parallel Cable Current Sharing: how a current divides between up to four parallel conductors from their lengths and the resistance per metre in your cable data.
  • Device Rating Ratio: the ratio of upstream to downstream device ratings against the minimum from the manufacturer's selectivity data, which alone does not prove selectivity.
  • Demand from Meter Readings: average demand from the energy recorded over an interval, with the load factor if you enter the peak, and the current at that average demand (not a design current) if you enter the voltage and power factor.
  • Fault Level at the End of a Cable: the three-phase fault current at the transformer terminals and at the end of a cable, from the transformer rating and impedance, your cable data and any voltage factor you enter.

Formula tools for renewables, storage and heating

  • PV String Voltage: the string's open-circuit voltage at the coldest cell temperature and maximum power voltage at the hottest, against the inverter's maximum DC voltage and MPPT minimum if you enter them.
  • Inverter DC/AC Ratio: the array's DC rating ÷ the inverter's AC rating, against a maximum ratio from the inverter datasheet if you enter one.
  • Battery Bank Configuration: the bank's voltage, capacity and energy from its cells or modules and how many are in series and in parallel.
  • Battery C-Rate: converts between a current and a C-rate for a battery's capacity, with the ideal time at that current; a real discharge takes less time and a real charge takes longer.
  • Off-Grid Battery Autonomy: the nominal battery capacity to run the loads for a number of days without charging, from the depth of discharge and efficiency you enter.
  • Heat Pump Electrical Input and Cost: the electrical input and current from the heat output and COP, and the yearly electricity use and cost from the space-heating demand and SCOP, with hot water from its own demand and COP.
  • Room Heat Loss: a simplified steady-state estimate from up to four elements' areas and U-values and the room's air changes, not a full heat-loss survey.
  • Electric Shower Temperature Rise: the outlet temperature at a given flow, the flow for a target temperature and the current at 230 V.
  • EV Range Added per Hour: the miles of range added each hour from the charger power, the charging efficiency and the vehicle's consumption.
  • Solar Self-Consumption Savings: the yearly saving from solar PV used on site and exported, with a simple payback from the system cost.

Formula tools for containment, cables and conversions

  • Conduit Fill: the percentage of a conduit's internal area taken by up to four types of cable, compared with the maximum fill you enter; it checks area only, not bends or the length of the pull.
  • Trunking Fill: the cable area, fill percentage and spare area of a trunking from its internal width and height and up to four types of cable, compared with the maximum fill you enter.
  • Cable Bending Radius: the smallest internal bending radius and internal bend diameter from a cable's overall diameter and the multiplier in the cable maker's data.
  • AWG and mm² Conversion: converts an AWG size to its diameter and area in mm², or a metric area to the nearest AWG size, with 1/0 to 4/0 named by their trade names; the nearest size is not an equivalent size for current rating.
  • Cable Power Loss and Cost: the power lost as heat in a single-phase or balanced three-phase cable from the current, length and resistance of one conductor at its running temperature (not the mV/A/m figure), with the yearly energy and cost if you enter the hours and unit price.
  • Conductor Resistance from Resistivity: the resistance of a copper or aluminium conductor from its length and area at 20 °C or another temperature; for a nominal size it usually reads a few per cent below the cable maker's figure, which is the one to use for loop impedance and voltage drop checks.
  • Cable Length from Resistance: an estimate of an installed cable's length from a measured resistance and the resistance per metre in your cable data.
  • Parallel Earth Electrodes: an estimate of the combined resistance of bonded electrodes from one electrode's measured resistance and the multiplying factor from your reference, to be confirmed by measuring the installed arrangement.
  • Point Illuminance: the illuminance at a point from one luminaire's intensity towards it, the mounting height or straight-line distance and the angle of incidence, by the inverse-square cosine law.
  • Energy Unit Conversion: converts an amount of energy between kWh, MJ, BTU, therms and kcal.

Formula tools for circuit checks, lighting layout, EV supply and site work

  • Voltage Drop from Resistance and Reactance: the voltage drop of a larger cable at the load's power factor from the resistive (r) and reactive (x) values in your cable data, with the drop using z for comparison; you enter r and x for your kind of circuit.
  • Minimum Conductor Size for Voltage Drop: a first estimate of the smallest copper or aluminium conductor that keeps voltage drop within your limit, from resistivity alone; it ignores reactance and does not check current rating or fault protection.
  • R1 + R2 from Conductor Sizes: the R1 + R2 to expect from a circuit's length and its line and protective conductor sizes, at 20 °C or another temperature; it usually reads a little below the cable maker's figure.
  • Three-Phase Fault Current from a Line–Neutral Reading: an estimate of the three-phase and line-to-line fault currents from a line–neutral loop impedance, assuming the neutral matches the lines; a reading taken between lines takes precedence.
  • Touch Voltage During an Earth Fault: the voltage on exposed metalwork during an earth fault from Zs and the protective conductor's resistance, compared with a value you enter from your reference.
  • Maximum Zs from a Device's Trip Current: the largest earth fault loop impedance that still gives the trip current you take from the device maker's time-current data, with the voltage factor you enter; a maximum Zs tabulated for the device takes precedence.
  • Combined Loads and Overall Power Factor: adds up to four loads with different power factors by their real and reactive parts, giving the total kW, kVAr and kVA, the overall power factor and the current.
  • Capacitor Size from kVAr: the capacitance that gives a reactive power rating at your voltage and frequency for a single-phase capacitor or a star or delta bank, with the line current.
  • Two-Wattmeter Power and Power Factor: the total power, reactive power and power factor of a balanced three-wire three-phase load from the two wattmeter readings.
  • RC Time Constant: the time constant of a resistor and capacitor and the capacitor voltage after a given time; a calculated time is never proof that a capacitor is discharged.
  • Room Index: the room index of a rectangular room from its size and the luminaire height above the working plane, for reading a utilisation factor from the luminaire maker's data.
  • Luminaire Spacing to Height Ratio: the spacing to height ratio of a lighting layout, compared with the maximum ratio from the luminaire maker's data.
  • Lamp Replacement Savings: the yearly energy and cost saved by replacing lamps with lower-power ones, with a simple payback on the cost of the work.
  • EV Charging Cost: the cost of a charge from the battery size, charge levels, charging efficiency and unit price, with the cost per mile if you enter the vehicle's consumption.
  • Current Available for an EV Charger: the current left for a charger after the existing maximum demand and any margin, from a supply capacity you enter; the distributor confirms whether the supply is adequate.
  • Cable Tray Width: the tray width needed for up to four types of cable in a single layer, with a gap between cables and spare space; it checks width only, not load or current ratings.
  • Conduit Offset Bend: the distance between the two bends of an offset and the length the run loses, from the offset height and bend angle, as a check beside your bender's own marks.
  • Power Unit Conversion: converts a power between watts, kilowatts, mechanical and metric horsepower and BTU per hour.
  • Temperature Conversion: converts a temperature between degrees Celsius, degrees Fahrenheit and kelvin.
  • Conductor Diameter and Area: the area of a round solid or stranded conductor from its strand diameter, or the strand diameter for an area; a cable's nominal size cannot be identified from a measured diameter alone.

Use a calculator

  1. 1

    Open Calculators and choose the tool.

  2. 2

    Choose the supply type where asked, for example single-phase or three-phase.

  3. 3

    Enter your values in the units shown. Where a tool asks for cable or device data, take it from the manufacturer's data or the current edition of the standard you work to.

  4. 4

    Read the result together with the assumptions and warnings shown beside it.

  5. 5

    Record the verified design values in your own design or certificate records.

What a result means

Results are preliminary checks from the values you enter. They are not a design approval or a compliance certificate, and they do not replace verification against the current regulations, the manufacturer's data and testing on site.

The competent person remains responsible for the design and for every value recorded on a certificate.

Common mistakes

  • Entering a phase-to-neutral voltage where the tool asks for line-to-line voltage, or the reverse.
  • Multiplying a single-phase mV/A/m value by √3 for a three-phase circuit. Voltage Drop takes the cable's single-phase value and converts it for you (× √3/2), then compares the drop between lines with the line voltage, 400 V by default.
  • Using cable data from the wrong reference method or the wrong table.
  • Treating an assistant's checklist as a finished design.

Troubleshooting

If a result does not appear, check that every required value is filled in and uses a full stop for decimals. If a result looks wrong, check the units first.